Archives

Category: General

What is the air quality requirement for acoustic cleaners?

The acoustic cleaner uses normal work air. The valve group of the cleaner has a filter/water separator to take out the impurities and water out of the work air.

This entry was posted in FAQ, General. Bookmark the permalink.

What is the required air supply pressure for the acoustic cleaners?

The air supply pressure should be 6 bars. While sounding the pressure can decrease to 4 bars.

This entry was posted in FAQ, General. Bookmark the permalink.

Can the outside noise level be reduced somehow?

The outside noise level can be reduced to under 85 dB measured from one meter distance of the generator by using a proper sound insulation box. Nirafon can provide these boxes or instructions and drawings to make proper sound insulation … Continue reading

This entry was posted in FAQ, General. Bookmark the permalink.

What is the outside noise level caused by acoustic cleaners?

The outside noise level caused by acoustic cleaner depends on the structures where it is installed. When installed to boiler wall the outside noise level is around 100 dB. The outside noise level of Nirafon NCSD does not exceed 85 … Continue reading

This entry was posted in FAQ, General, NCSD. Bookmark the permalink.

What is the maximum temperature for acoustic cleaner pneumatic equipment?

The maximum temperature for the pneumatic equipment is 50 ˚C.

This entry was posted in FAQ, General. Bookmark the permalink.

What is the maximum temperature for acoustic cleaner generator?

The maximum temperature of the generator is around 200 ˚C. When the cleaner is installed into a hot position the cooling air into the cleaner has to always flow to the cleaner.

This entry was posted in FAQ, General. Bookmark the permalink.

What is the maximum temperature for horn materials?

Nirafon horns are made of SS2342 (AISI316) acid proof steal and in the higher temperature areas the mouth cone of the horn is usually made of G-X15-CrNiSi229. These materials can take the temperatures up to: SS2343 c. 1000˚C and G-X15-CrNiSi229 … Continue reading

This entry was posted in FAQ, General. Bookmark the permalink.

Does the acoustic cleaning cause some risks to boiler structures?

- Nirafon acoustic cleaners use only acoustic frequencies (audible to human ear 16…16000Hz). The natural frequency of boiler structures is below this acoustic level. Frequencies below 20 Hz could cause the structures to resonate because of the sound and cause … Continue reading

This entry was posted in FAQ, General. Bookmark the permalink.